      Home > Products > Low Voltage

      GCK Low-voltage switch cabinet

      Brand: RENDA
      Model: GCK
      Updated: 2015/10/29
      • Product description
      • Scope of application
      • Product features
      • Technical parameters

      1. Product overview  

       
      GCK switchgear full name GCK indoor withdrawable low-voltage switchgear.
       
      GCK switchgear is based on the standard design drawings of Tianjin Electric Transmission Research Institute, the focal point of the national low-voltage industry, combined with our experience in manufacturing rooms.
       
      This equipment conforms to the International Electrotechnical Commission IEC439-1 "low-voltage switchgear and control equipment", China's GB7251-1997 "low-voltage switchgear and control equipment", China's national standards and machinery industry association JB/T9661-1999 standard content, and in line with CQC's CCC national compulsory certification standard. 
       
      2. Product use
       
      It is used for power reception, feeding, reactive power compensation, energy measurement, lighting and centralized control of motors in power plants, substations, industrial and mining enterprises and high-rise buildings of power systems.
       
      3. Environmental conditions of product use
       
      (1) The ambient air temperature is not higher than +40 °C, not less than -5 °C, and its average temperature is not higher than +35 °C within 24 hours.
       
      (2) The ambient air temperature is +40 °C, the relative temperature does not exceed 50%, and the higher relative temperature at the lower temperature, such as +20 °C, the temperature is allowed to be 90%, but it should be examined
       
      It is considered that condensation may occur due to temperature changes.
       
      (3) For indoor use, the altitude of the place of use shall not exceed 2000M.
       
      (4) It should be installed in a place where there is no severe vibration and impact to make the electrical components corroded.
       

      This equipment is suitable for power plants, substations, large buildings, high-rise buildings, airports, hospitals, theaters, stadiums, ports, underground facilities, industrial and mining enterprises, etc. It is used for power generation, feeding, and motor control in AC 380V systems below 2000KVA.

      1. Designed with high-current unit, and low-current multi-loop unit

       

      2. The small doors of the two drawers on the same floor in the same cabinet are independent and do not interfere with each other

       

      3. Compact structure, flexible assembly, reasonable distribution, neat arrangement, less floor space

       

      4. Firm structure, reliable connection, high degree of protection and complete functions

       

      5. Safe and simple operation, good interchangeability performance, large short-term withstand current

       

      6. Unique compatible form, can install domestic and imported various series of circuit breakers

       

      Product structure features:

       

      The basic frame of GCK is a combined assembly structure, all structural parts of the cabinet frame are galvanized, sprayed with plastic, connected to each other by dowel fastening to form a basic cabinet frame, and then added doors, baffles, partitions, flexion, mounting brackets, busbars and electrical components and other parts as needed to assemble into a complete control center cabinet. The structure of this cabinet has the following characteristics:

       

      1. Cabinet shelf

       

      The cabinet frame is assembled from C profile, and the special supporting parts of the cabinet frame parts are supplied by the company to ensure the accuracy and quality of the cabinet.

       

      a. The molding size, opening size, and equipment interval of parts are modularized.

       

      b. The internal structural parts are galvanized.

       

      c. The top cover of the cabinet body is foldable, and the top cover can be removed.

       

      d. The outside is phosphated; then electrostatic epoxy powder is sprayed.

       

      e. The cabinet frame is pided into three mutually isolated sections: busbar room, functional unit room and cable room, which can prevent the spread of accidents and facilitate live maintenance.

       

      2. Functional unit (flexion part)

       

      a. Functional unit: feed unit, motor unit, common power supply unit.

       

      b. The height modulus of the extraction unit is 200mm, which is pided into five size series: 1/2 unit, 1 unit, 1.5 unit, 2 unit and 3 unit. The rated current of the unit loop is 630A or less.

       

      c. Each MCC cabinet can be installed with up to 9 one-unit drawers or 18 1/2-unit drawers.

       

      d. The door panel of the isolation room is mechanically interlocked with the extraction by the operating mechanism of the main switch, and the extraction cannot be withdrawn when the main switch is in the closed position.

       

      e. The operating mechanism of the main switch can be locked in the closing or opening position with a padlock, which can safely carry out the maintenance of electrical equipment.

       

      f. The back of the functional unit has a main circuit burst wire plug, an auxiliary circuit secondary plug and a grounding plug.

       

      g. The grounding plug makes the extraction in the connection position of the separation test, which ensures the continuity of the protection circuit.

       

      h. The functional unit compartment is separated by a metal partition.

       

      i. The flap in the compartment automatically opens and closes as the extraction advances and pulls out, so that the vertical busbar is not touched in the large compartment.

       

      J. The flexion unit adopts a rotary spreading mechanism, which has a three-position function, and the operation is simple and reliable.

       

      k. Description of the suction operation mechanism

       

      The extraction and thrusting mechanism (hereinafter referred to as the mechanism) adopts the movement mode of the dowel trajectory along the positioning part to realize the advancement and extraction of the functional unit, and in the process of the promotion and extraction of the functional unit, the three-position display and mechanical interlock and the reverse electrical interlock can be retrograde when the test position of the micro switch is equipped to avoid personal or equipment accidents and meet the relevant national and industry standards. This product is small in size and flexible in installation. Reliable performance.

       

      3. Busbar system

       

      a. The vertical busbar is closed with polycarbonate plastic shell.

       

      b. GCK, bus system adopts three-phase four-wire system, three-phase five-wire system, horizontal busbar installed on the top of the cabinet, N line, PE line can be installed on the top of the cabinet, can also be installed in the lower part of the cabinet.

       

      c. The three-phase horizontal busbar adopts copper busbar, which has high mechanical strength and good heat dissipation.

       

       

      Standards and technical specifications

      Low-voltage switchgear and control equipment (TTA) that have passed the type test, and low-voltage pumping switchgear

      IEC439.1-1992

      GB7251.1-1997

      JB/T9661-1999

      Overvoltage category

      IV

      III

      Pollution level

      3

       

      Rated two working voltage (Ve).

      660V

      380A

      Rated frequency

      50HZ

       

      Horizontal busbars

      Rated current (A).

      3150 2500 2000 1000

       

      Rated short-time withstand current (KA).

      50 (IS rms).

       

      Rated peak withstand current (KA).

      105

       

      Vertical busbar

      Rated current

      1400A

      1000A

      Rated short-time withstand current (KA).

      50KA

       

      Rated peak withstand current (KA).

      105

       

      Various device ratings

       

       

      Circuit breaker unit (A).

      to 4000

       

      Extraction unit, main contact rated current

      800-200

       

      Reactive power compensation unit cabinet maximum power (kVar).

      300

       

      Enclosure rating

      IP40、IP30

       

      ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號  
      日本乱偷人妻中文字,女人自慰A√片高清免费,国产乱子伦一区二区三区=,精品国内自产拍在线观看
    • <menuitem id="jvll6"><dl id="jvll6"></dl></menuitem>
      <samp id="jvll6"><tfoot id="jvll6"></tfoot></samp>
    • <samp id="jvll6"></samp>
      <fieldset id="jvll6"><table id="jvll6"><kbd id="jvll6"></kbd></table></fieldset>
      • <menuitem id="jvll6"><dl id="jvll6"><pre id="jvll6"></pre></dl></menuitem>