      Home > Products > High Voltage

      DFW-12 Cable Distribution Box

      Brand: RENDA
      Model: DFW-12
      Updated: 2015/10/28
      • Product description
      • Scope of application
      • Product features
      • Technical parameters

      1. Product overview

      This product is using sulfur hexafluoride load switch or vacuum switch as a control switch (can also not be installed), using touchable shielding silicone rubber cable connector, with strong load and no-load cable current breaking ability and short circuit current closing ability, and can be equipped with lightning arrester and ground fault indicator according to user requirements.

      Load switches or vacuum short-circuits can be installed on each ring network connection line in this product, and any branch circuit can be freely exited and put into operation, while other ring network circuits are not affected. A fuse can also be installed on the load switch to quickly disconnect the fault circuit, and hit the trip of the load switch to open it, and the fault circuit is isolated, so as to ensure the continuity of power supply of the circuit of the fault branch.

       

      2. Product use

      DFW-12 cable distribution box is widely used in relay distribution and power distribution of power system. It is an important electrical equipment for outdoor cable collection and distribution, and the distribution box is divided into ordinary cable distribution box and cable distribution box with switch. It can also be divided into ordinary type and flood protection type according to the sealing level. It is widely used in cities and areas where industrial and mining enterprises are concentrated. It is the first choice product to realize the cable transformation of urban power grid and realize fast power supply of ring network.

      3. Environmental conditions of product use

       (1) The altitude does not exceed 1000m. Note: When the altitude exceeds 1000m, consultation with the manufacturer is required.

       (2) The ambient temperature is not higher than +40 °C, and the average temperature within 24 hours does not exceed +30 °C. The ambient temperature is not less than -30°C.

       (3) There is no explosion and flammable danger in the surrounding medium, no gas or vapor that is sufficient to damage the insulation and corrosive metal, and no conductive dust.

       (4) No severe vibration and bumps, installation inclination is not more than 5°.

      This product is widely used in cable tap in 10KV power system. And the connection method is simple, flexible and convenient, safe and reliable. The cabinet body is made of 2 mm stainless steel, which is strong and durable. The live part is fully insulated and fully sealed structure. If the cable head is touchable for flood protection, it can also withstand flood invasion. Greatly improve the reliability of power supply. The product is widely used in urban industrial areas, residential areas, commercial centers, mining area airports, railways, wind power stations, opening and closing stations and steel, petrochemical, cement and other large enterprises and distribution networks, projects, can greatly save the investment of electrical equipment and cables, improve reliability.

      (1) Air insulation is adopted.

      (2) Expandable for distribution automation.

      (3) Compact structure, flexible assembly, reasonable distribution, neat arrangement, less floor space, high degree of protection, complete functions.

      (4) Safe and simple operation, good interchangeability performance, large short-term withstand current.

      (5) Unique compatible form, can install domestic and imported various series of circuit breakers.

      Name

      Parameters

      Rated voltage

      12KV

      Rated frequency

      50Hz

      Rated current

      The inlet and feed are 630A

      Dynamically stabilize the current

      50kA (peak).

      Thermally stable current

      20kA (RMS) 4s

      Insulation level

      Power frequency withstand voltage between phases, relative ground 42kV/1min

      Impact pressure

      Interphase, relative 75 kV (1.2/50 μs).

      Degree of protection

      IP34

      ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號  
      日本乱偷人妻中文字,女人自慰A√片高清免费,国产乱子伦一区二区三区=,精品国内自产拍在线观看
    • <menuitem id="jvll6"><dl id="jvll6"></dl></menuitem>
      <samp id="jvll6"><tfoot id="jvll6"></tfoot></samp>
    • <samp id="jvll6"></samp>
      <fieldset id="jvll6"><table id="jvll6"><kbd id="jvll6"></kbd></table></fieldset>
      • <menuitem id="jvll6"><dl id="jvll6"><pre id="jvll6"></pre></dl></menuitem>