      Home > Products > UPS power supply

      Solar PV inverter

      Brand: RENDA
      Model: RD500
      Updated: 2015/10/29
      • Product description
      • Scope of application
      • Product features
      • Technical parameters

      Photovoltaic inverter is an inverter used in solar photovoltaic power generation system and is an important component of photovoltaic system.

      Photovoltaic inverters are mainly used in the field of photovoltaic power generation.

      product features

      ● The controller module is controlled by M P P T and the maximum conversion efficiency is as high as 9 7 %.

      ●modular design, Strong compatibility and easy maintenance

      ● adopt digital control strategy , the whole machine control is flexible and accurate

      ● Perfect protection and alarm functions , which makes the system have high reliability

      ●The output adopts power frequency transformer isolated output , high security, high reliability

      ●Intelligent artificial interface , which can visually display various parameter information of the product

      ●Rich menus, Easy to upgrade and expand.

      automatic operation and shutdown function

      after sunrise in the morning, the solar radiation intensity gradually increases, and the output of the solar cell also increases, and when the output power required for the inverter to work is reached, the inverter automatically starts to operate. After entering operation, the inverter will monitor the output of the solar cell module at all times, as long as the output power of the solar cell module is greater than the output power required for the inverter to work, the inverter will continue to run until sunset shutdown, even on rainy days the inverter can operate. When the output of the solar cell module becomes smaller and the output of the inverter approaches 0, the inverter forms a standby state.

      maximum power tracking control function

      the output of the solar cell module varies with the intensity of solar radiation and the temperature of the solar cell module itself (chip temperature). In addition, since solar cell modules have the characteristic that the voltage decreases with the increase of current, there is an optimal operating point to obtain the maximum power. The intensity of solar radiation varies, and obviously the optimal operating point is also changing. Relative to these changes, the operating point of the solar cell module is always at the maximum power point, and the system always obtains the maximum power output from the solar cell module, this control is the maximum power tracking control. The biggest feature of inverters for solar power generation systems is that they include the function of maximum power point tracking (M P P T ).

      solar PV inverter (technical  parameters )

       Model No.

      RD500

      RD1000

      RD1500

      Rated capacity

      500W

      1000W

      1500W

      Inverter mode

      PV input voltage range

      33-60Vdc

      Rated battery voltage

      24Vdc

      Battery float voltage

      27.2Vdc

      Rated output voltage (V)

      220Vac

      Rated output frequency (Hz)

      50Hz±1Hz

      Output voltage range

      ±2%Vrms

      Output current

      2.27A

      4.54A

      6.8A

      Output voltage waveform distortion

      Less than or equal to 2%

      Efficiency

      More than 80%

      Controller efficiency

      Greater than 955

      Quiescent current

      Less than or equal to 3% Irms

      The peak factor

      3

      Overload protection

      When 125% overload, the output is disconnected after 60 seconds; When 150% overloaded, disconnect the output after 10 seconds

      Switching time

      Less than 3ms

      Mains mode

      Mains input voltage range

      220V±10%Vac

      Mains input frequency

      50Hz±1Hz

      System parameters

      Display mode

      LCD+LED

      Display content

      Electrical measurement, battery capacity, input voltage, output voltage, load, temperature

      Communication

      RS232+RS485 (communication function optional)

      Cooling method

      Intelligent air-cooled

      Protection function

      High voltage, undervoltage, overfrequency, underfrequency, short circuit, overcharge,

      overdischarge, overtemperature, overload protection

      Isolation method

      Power frequency transformer

      Ambient temperature

      -10℃-50℃

      Ambient humidity

      Less than or equal to 93% (non-condensing)

      Noise

      Less than 60dB

      Altitude Less than or equal to 1000m

      , greater than 1000m to reduce the capacity of

      ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號  
      日本乱偷人妻中文字,女人自慰A√片高清免费,国产乱子伦一区二区三区=,精品国内自产拍在线观看
    • <menuitem id="jvll6"><dl id="jvll6"></dl></menuitem>
      <samp id="jvll6"><tfoot id="jvll6"></tfoot></samp>
    • <samp id="jvll6"></samp>
      <fieldset id="jvll6"><table id="jvll6"><kbd id="jvll6"></kbd></table></fieldset>
      • <menuitem id="jvll6"><dl id="jvll6"><pre id="jvll6"></pre></dl></menuitem>