      Home > Products > UPS power supply

      1-3KVA Power UPS power supply

      Brand: RENDA
      Model: RDH1-3KVA
      Updated: 2016/4/26
      • Product description
      • Scope of application
      • Product features
      • Technical parameters

      RDH series special UPS (special inverter power supply) is a special power supply product designed for uninterrupted AC power supply systems such as power plants, substations, distribution stations, post and telecommunications, railways, etc., with double conversion online, zero conversion and fault bypass functions. This series of products is using advanced DSP digital control technology, high-frequency switching technology, so that the series of products better quality, better performance, easier to install and maintain.

      RDH series special UPS (special inverter power supply) is a special power supply product designed for uninterrupted AC power supply systems such as power plants, substations, distribution stations, post and telecommunications, railways, etc.

      ◆ Fully adopt DSP digital control technology, the product is more stable and the quality is superior.

      ◆ DC self-start function, in DC mode, DC voltage out of range, dedicated UPS turn off the output, when it returns to normal value, dedicated UPS automatically boots.

      ◆ The load power factor is 0.8, which is designed according to the latest electrical equipment standards.

      ◆ Active input power factor correction (PFC) is as high as 0.98 or more, avoiding pollution to the power grid environment and meeting the social requirements of energy conservation and environmental protection.

      ◆ Wide input voltage frequency range can supply power normally even in remote areas with very harsh power environment, reducing the number of battery discharges and improving the service life of the battery.

      ◆ When the zero switching mains power is unstable, the conversion time of the UPS power supply mode is zero, which effectively ensures the safety and reliability of load operation.

      ◆ Convenient remote monitoring function, providing standard RS232 interface, optional dry contact, RS485, and network monitoring card.

      Product Model 
      Properties and parameters
      RDH1K-48/100/220
      RDH2K-48/100/220
      RDH3K-48/100/220
      Rated output capacity
      1000VA/800W
      2000VA/1600W
      3000VA/2400W
      Communication
      Enter
      Rated voltage
      220Vac/230Vac/240Vac
      Rated frequency
      50Hz/60Hz
      Input voltage range
      (172~268)±7Vac
      Input frequency range
      (45~55)±0.5Hz
      AC input harmonics
      <3%.
      Charge
      Charging current
      5-7A (charging function, optional function).
      DC
      Enter
      DC rated voltage
      48Vdc/110Vdc/220Vdc
      48V
      Communication systems
      Rated current
      19.6A
      39.2A
      58.8A
      DC voltage range
      40-58V
      Enter the low voltage alarm/protection point
      40/42V
      Enter the high voltage alarm/protection point
      58/58V
      110V
      Power system
      Rated current
      8.6
      17.2
      25.8
      DC voltage range
      90-130V
      Enter the low voltage alarm/protection point
      95/90V
      Enter the high voltage alarm/protection point
      130/130V
      220V
      Power system
      Rated current
      4.3
      8.6
      12.9
      DC voltage range
      180-260V
      Enter the low voltage alarm/protection point
      190/180V
      Enter the high voltage alarm/protection point
      260/260V
      Exchange Output
      Output voltage
      220Vac±3% (inverter output).
      Output frequency
      50±5Hz (when AC input is normal), 50Hz±1% (when AC input is abnormal).
      Dynamic voltage transients
      <5%.
      Dynamic transient recovery time
      < 60ms
      Waveform
      Sine wave THD <3% (linear load); THD <8% (nonlinear load).
      Output power factor
      0.8
      Overload capacity
      130% for not less than 20s
      Output current peak factor
      3:1
      DC and AC conversion time
      0ms
      How the panel is displayed
      LCD/LED optional
      Communication functions
      Standard RS232+ smart slot, smart slot expandable RS485, dry node, SNMP and other monitoring functions.
      Protection features
      DC input overvoltage, undervoltage protection, overload protection,
      overtemperature protection, short circuit protection, output overvoltage, low voltage protection
      SIZE (W*H*D) MM
      432*88*300
      432*88*440
      Weight Kg
      6.5
      9.5
      10
      ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號  
      日本乱偷人妻中文字,女人自慰A√片高清免费,国产乱子伦一区二区三区=,精品国内自产拍在线观看
    • <menuitem id="jvll6"><dl id="jvll6"></dl></menuitem>
      <samp id="jvll6"><tfoot id="jvll6"></tfoot></samp>
    • <samp id="jvll6"></samp>
      <fieldset id="jvll6"><table id="jvll6"><kbd id="jvll6"></kbd></table></fieldset>
      • <menuitem id="jvll6"><dl id="jvll6"><pre id="jvll6"></pre></dl></menuitem>