      Home > Products > High Voltage

      Compressed air-type ring counter (with VI switch)

      Brand: RENDA
      Model:
      Updated: 2015/10/28
      • Product description
      • Scope of application
      • Product features
      • Technical parameters

       1. Product overview

       "Ring network cabinet" is a collective term for load switchgear and combination electrical cabinet applied to ring network supply units. The ring network cabinet has the advantages of non-oil, non-toxic, non-burning fire and explosion hazard, and is equipped with manual and electric operating mechanisms at the same time, which provides the prerequisites for automatic control and remote control. HXGN type indoor high voltage vacuum load switchgear (ring network cabinet) is a three-phase AC indoor high voltage power distribution equipment.

      It is suitable for indoor AC high voltage complete sets with rated voltage 3.6-12kV and rated frequency of 50Hz. It conforms to the national standard GB3906-91 "3-35kV indoor AC metal-enclosed switchgear", KL404/T "Indoor AC high-voltage switchgear ordering technical conditions" and the International Working Committee IEC-298 "AC metal-enclosed switchgear and control equipment" standard.

      2. Product use

      It is suitable for

      10kV ring network power supply unit and terminal power supply unit for accepting, controlling and distributing electric energy, especially suitable for the protection of distribution transformers, so it is widely used in urban power grids, industrial and mining enterprises, residential areas, high-rise buildings, schools, parks and other places of power distribution systems.

      3. Environmental conditions of product use

      (1) Altitude: not more than 1000m;

      (2) Ambient temperature: -25°C~+40°C;

      (3) Surrounding relative humidity: daily average is not more than 95%, monthly average is not more than 90%;

      (4) The surrounding air should be free from obvious pollution such as corrosive or flammable gases, water vapor, etc., without regular violent vibration;

      (5) Earthquake intensity: 8 degrees.

      When the conditions of use are different or there are special requirements, it is necessary to negotiate with the manufacturer.

      4. Product model name  

      HXGN *-* Z.R
      ││││   │ │   
      ││││   │ │   
      ││││ │   └──────Vacuum fuse combination electrical
      ││││   └───────Rated voltage (KV)
      │││└─────────────Design serial number
      ││└────────Indoor
      │└───────────——Stationary
      └────────────Ring cage type

       

      Suitable for power systems, industrial power distribution, high-rise buildings, outdoor switch boxes, box substations and other places

      1. It adopts advanced rotary compressed gas arc extinguishing technology, and the arc extinguishing ability is stronger. The air box is made of 3mm thick stainless steel material welded by advanced laser technology, and the product structure has high strength, good air tightness and beautiful appearance.

       

      2. Unique visual window design, convenient for the state observation of load switch, making the operation more safe and reliable.

       

      3. The product design fast grounding switch to ensure that the equipment can be safely and reliably grounded.

       

      4. 90% of the materials used are metal materials, and when the service life of the product expires, it can be recycled without causing damage to the environment.

       

      5. In order to meet the requirements of different user installations, two expansion methods are designed: side expansion (side expansion) and top expansion (top expansion).

       

      6. With a convenient combination scheme, not only products with common box modules, but also products with single modules, the combination is more convenient and flexible.

       

      7. Load switch, load switch-fuse combination electrical appliance, circuit breaker functional unit module width is consistent, small size, convenient for installation in space-constrained places.

       

      Serial number

      Name

      Unit

      Technical parameters

      1

      Rated current

      A

      630

      1250

      2

      Rated voltage

      kV

      12

      3

      Rated frequency

      Hz

      50

      4

      Rated insulation level

      1 minute power frequency withstand voltage

      Relatively, interstitily

      kV

      42

      Breaks

      kV

      48

      Lightning impulse withstand voltage

      Relatively, interstitily

      kV

      95

      Breaks

      kV

      110

      5

      Load switch

      Rated current

      A

      630

      1250

      Rated short-time withstand current

      kA

      25

      Rated peak withstand current (peak).

      kA

      63

      Rated short-circuit closing current (peak).

      kA

      63

      Closing speed

      m/s

      ≥6

      Opening speed

      m/s

      4.5-6

      The three-phase opening is in different stages

      ms

      10

      The three-phase closing gate is in different periods

      ms

      10

      Corners

      degree

      120

      Break opening

      mm

      228

      6

      Grounding switch

      Rated voltage

      kV

      12

      Rated short-time withstand current

      kA

      25

      Rated peak withstand current (peak).

      kA

      63

      Rated short-circuit closing current (peak).

      kA

      63

      Closing torque

      N.m

      ≤60

      Opening torque

      N.m

      ≤100

      7

      Grounding switch

      Rated active load breaking current

      kA

      630

      1250

      Rated closed-loop breaking current

      kA

      630

      1250

      Rated cable charging and breaking current

      A

      10

      8

      Rated short-circuit breaking current

      kA

      31.5

      9

      Rated transfer current

      A

      1250

      10

      The auxiliary loop and the control loop are rated power frequency withstand current

      kA

      2

      11

      The distance between the centers

      mm

      170(210)

      12

      Phase and relative air distance

      mm

      ≥125

      13

      Main loop resistance

       

      <105

      14

      Mechanical life

      times

      2000

      15

      Enclosure rating

       

      IP2X

      16

      Cabinet external dimensions

      HXGN□-10/630 (side-mounted load switch).

      mm

      650X910X1860

      HXGN□-10 (built-in FZN21 load switch).

      mm

      830X860X1860

      17

      Combination appliances

      Maximum rated current of the fuse

      A

      100

      Rated transfer current

      A

      1500(2000)

      Rated short-circuit breaking current

      kA

      31.5

      Fuse model is available

       

      S□LAJ-12(XRNT□-10)

      Equipped with transformer rated capacity

      kVA

      1250

      18

      The operating voltage of the electric operating mechanism

      V

      AC and DC 220

      19

      The rated current of the main busbar

      A

      630

      20

      The user's internal vacuum load switch is adopted, and the combination electrical appliance is used as the main switch, and its rated transfer current is 2000A, and the mechanical life is met.

                     
      ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號  
      日本乱偷人妻中文字,女人自慰A√片高清免费,国产乱子伦一区二区三区=,精品国内自产拍在线观看
    • <menuitem id="jvll6"><dl id="jvll6"></dl></menuitem>
      <samp id="jvll6"><tfoot id="jvll6"></tfoot></samp>
    • <samp id="jvll6"></samp>
      <fieldset id="jvll6"><table id="jvll6"><kbd id="jvll6"></kbd></table></fieldset>
      • <menuitem id="jvll6"><dl id="jvll6"><pre id="jvll6"></pre></dl></menuitem>