      PGL1 / 2 AC low voltage distribution panel

      Brand: RENDA
      Model: PGL1 / 2
      Updated: 2015/10/28
      • Product description
      • Scope of application
      • Product features
      • Technical parameters

      1. Product overview

       

      PGL2 AC low-voltage distribution panel, the cabinet body is made of high-quality steel plate, cold bent welding, with reasonable structure, safe circuit configuration, good protection performance, high breaking capacity, good dynamic and thermal stability, safe and reliable operation and other advantages. It is a new generation of low-voltage switchgear and the preferred product for grid transformation.

       

      The technical performance of this product conforms to GB7251 and GB4720 standards.

       

      2. Product use

       

      PGL1 AC low-voltage distribution panel is used in power plants, substations, industrial and mining enterprises AC 50HZ, rated working voltage does not exceed AC 380V low-voltage distribution system as power, distribution, lighting, use.

       

      3. Environmental conditions of product use

       

      (1) The ambient air temperature is not higher than +40 degrees, not less than -5 degrees, and the average temperature within 24 hours shall not be higher than +35 degrees.

       

      (2) The air is clean, the relative humidity does not exceed 50% when the maximum temperature is 40 degrees, and when the temperature is low, higher relative humidity is allowed. For example, +20 degrees 90%。

       

      (3) The altitude does not exceed 2000m.

       

      (4) The installation inclination does not exceed 5 degrees.

       

      (5) Places without severe vibration and impact and places that are not sufficient to corrode electrical components.

      Used in power plants, substations, industrial and mining enterprises, etc.

      PGL1, 2 AC low-voltage distribution panel has the advantages of reasonable structure, safe circuit configuration, good protection performance, high breaking capacity, good dynamic and thermal stability, safe and reliable operation, etc., and is a new generation of low-voltage switchgear and the preferred product for power grid transformation. Each main circuit scheme of this product corresponds to one or several auxiliary circuit schemes. After selecting the main circuit scheme, the user can easily select the appropriate electrical schematic diagram from the corresponding auxiliary circuit scheme, thereby reducing the user's design workload and improving work efficiency; The multi-circuit small motor control scheme is eliminated, and the main circuit scheme is more concise and reasonable. For the control scheme of multi-circuit small motor, it is recommended to choose the power box series products; The screen width of this product is pided into four types: 400, 600, 800, 1000mm, each screen can be used as an independent unit, and can also be combined with the screen as a unit into a variety of different schemes, so that users can choose.

       

      Structural features of this product:

       

      1. This product is a low-voltage power distribution device with indoor fixed installation and open double-sided maintenance.

       

      2. Its shell is made of thin steel and angle steel welded combination, there is a door in front of the screen, the dashboard above the screen is an open small door, can be equipped with an indicator instrument, and the assembled screen is bent between the steel plate bent partition, which reduces the possibility of the accident expansion due to the internal failure of a unit (one screen), above the skeleton behind the screen, the main bus bar equipped with a protective cover is installed on the insulation frame, effectively preventing the malignant accident of short circuit of the main bus bar caused by falling metal objects above.

       

      3. On the bottom of the second screen of the neutral busbar setting, there is a protective paint layer inside and outside the shell, and the terminal screen of the beginning screen can be added with a protective plate.

       

      4. This product has a good protective grounding system, the main grounding point is welded under the skeleton, and the instrument door also has a grounding point connected to the shell. This constitutes a complete grounding protection circuit. Due to the reliability of this grounding protection circuit, the protection against electric shock of the operator is greatly enhanced.

      Name

      Parameters

      Rated operating voltage

      AC380Y

      Rated frequency

      50/60HZ

      Rated current

      ≤2500A

      Rated short-time withstand current (1s).

      50kA

      Rated peak withstand current

      105kA

      Dielectric strength

      2500V/1min

      Rated insulation voltage

       660V

      ? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號(hào)  
      日本乱偷人妻中文字,女人自慰A√片高清免费,国产乱子伦一区二区三区=,精品国内自产拍在线观看
    • <menuitem id="jvll6"><dl id="jvll6"></dl></menuitem>
      <samp id="jvll6"><tfoot id="jvll6"></tfoot></samp>
    • <samp id="jvll6"></samp>
      <fieldset id="jvll6"><table id="jvll6"><kbd id="jvll6"></kbd></table></fieldset>
      • <menuitem id="jvll6"><dl id="jvll6"><pre id="jvll6"></pre></dl></menuitem>